3 Phase Voltage Monitor
WVM Series
Motor Protector
The WVM Series provides protection against premature equipment (motor) failure caused by voltage faults on the 3 Phase Line. The WVM’s microcontroller design provides reliable protection even if regenerated voltages are present. It combines dependable fault sensing with a 10 fault memory and a 6 LED status display. Part instrument, part control, the WVM protects your equipment when you’re not there and displays what happened when you return. The WVM is fully adjustable and includes time delays to prevent nuisance tripping and improve system operation. Time delays include a 0.25 to 30 s adjustable trip delay, an adjustable 0.25 to 64 m (in 3 ranges) restart delay, plus a unique 3 to 15 s true random start delay. The random start delay prevents voltage sags caused by simultaneous restarting of numerous motor loads after a power outage.
-
Protects Against:
-
10 Fault Memory & Status Displayed on 6 LED Readout
-
Switch Selectable Automatic Restart, Delayed Automatic Restart, & Manual Reset
-
Isolated 10 A SPDT Relay Contacts
-
ASME A17.1 rule 210.6
-
NEMA MG1 14:30, 14:35
-
IEEE C62.41 - 1991 Level B
Universal 3 Phase Voltage Monitor
DLMU & DLMH Series (SPDT & N.O. or N.C.)
Motor Protector
The DLMU Series is a universal voltage, 3 Phase Voltage Monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses Phase Reversal, Over, Under and Unbalanced voltages including Phase Loss and over or under frequency. Protection is assured during periods of large average voltage fluctuations or when regenerated voltages are present. The unit trips within 200 ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The 10A isolated SPDT and 2A alarm output relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss set point and the acceptable frequency range are fixed. Both Delta and Wye systems can be monitored; no connection to neutral is required.
-
Protects Against:
-
35 mm DIN Rail or Surface Mounting
-
SPDT Isolated 10A Relay Contact
-
N.O. or N.C. SPST Isolated 2A Relay Contact
-
LED Indicates: Relay, Faults, & Time Delays
-
Universal Line Voltage 240 - 480 V AC in One Unit
-
600 V AC Version Available
-
3 Wire Connection for Delta or Wye Systems
-
ASME A17.1 rule 210.6
-
NEMA MG1 14:30, 14:35
-
IEEE C62.41 - 1991 Level B
Universal 3 Phase Voltage Monitor
HLMU Series (DPDT)
Motor Protector
The HLMU Series is a universal voltage, encapsulated, 3 Phase Voltage Monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses Phase Reversal, Over, Under and Unbalanced voltages including Phase Loss and over or under frequency. Protection is assured during periods of large average voltage fluctuations, or when regenerated voltages are present. The unit trips within 200 ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The 10A isolated DPDT output relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss set point and the acceptable frequency range are fixed. Both Delta and Wye systems can be monitored; no connection to neutral is required.
-
Protects Against:
-
Encapsulated Circuitry
-
DPDT Isolated 10 A Contacts
-
LED Indicates Relay Status, Faults, & Time Delays
-
Universal Line Voltage 200 - 480 V AC in One Unit
-
Compact, Encapsulated Design
-
Finger-Safe Terminal Blocks, up to 12 AWG
-
ASME A17.1 rule 210.6
-
NEMA MG1 14:30, 14:35
-
IEEE C62.41 - 1991 Level B
3 Phase Voltage Monitor
PLMU Series
Universal Plug-in Monitor
The PLMU Series continuously measures the voltage of each of the three phases to provide protection for three phase motors and sensitive loads. Its microcontroller senses under and over voltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Universal voltage operation and standard base connection allows the PLMU to replace hundreds of competitive part numbers.
-
Protects Against:
-
Phase Loss
-
Phase Reversal
-
Overvoltage
-
Undervoltage
-
Underbalanced Voltages
-
Octal Plug-in with SPDT Isolated 10 A Contacts
-
Operates from 200 - 480 V AC
-
LED Indicator Glows Green when Voltages are Acceptable, Red for Faults
-
Easier to Install - Indicates Reverse Phase Wiring
-
Simple 3-Wire Connection for Delta or Wye Systems
-
ASME A17.1 rule 210.6
-
NEMA MG1 14:30, 14:35
-
IEEE C62.41 - 1991 Level B
3 Phase Voltage Monitor
PLM Series
Motor Protector
The PLM Series continuously measures the voltage of each of the three phases. The PLM Series uses a new microcontroller circuit design that senses Undervoltage, Voltage Unbalance, Phase Loss, and Phase Reversal. Protection is assured when regenerated voltages are present. Both Delta and Wye systems can be monitored; no connection to neutral is required.
-
Protects Against:
-
Phase Loss
-
Phase Reversal
-
Undervoltage
-
Unbalanced Voltages
-
8 Pin Plug-in Base
-
Adjustable Low Voltage Trip Point
-
Factory Fixed Unbalance and Trip Delay
-
Line Voltages 200 - 480 V AC, in 3 Ranges
-
SPDT Isolated 10 A Relay Contacts
-
ASME A17.1 rule 210.6
-
NEMA MG1 14:30, 14:35
-
IEEE C62.41 - 1991 Level B
Compact 3 Phase Voltage Monitor
TVW Series The NetTM
Motor Protector
Provides protection for motors and other sensitive loads. Continuously measures the voltage of each of the three phases using a new microcontroller circuit design that senses under and overvoltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Includes a trip delay to prevent nuisance tripping and a restart delay to prevent short cycling after a momentary power outage.
-
Protects Against:
-
Phase Loss
-
Phase Reversal
-
Undervoltage
-
Overvoltage
-
Unbalanced Voltages
-
Short Cycling
-
Fixed Trip Points and Delays
-
Adjustable Voltages from 208 - 480 V AC in 4 Ranges
-
Monitor 600 V AC Lines by Connecting VRM Accessory
-
Isolated 10 A, SPDT Relay Contacts
-
Bi-color LED indicator Shows:
-
Output Status
-
Faults
-
Time Delays
-
Phase Reversal
-
Set Point
- ASME A17.1 rule 210.6
-
NEMA MG1 14:30, 14:35
-
IEEE C62.41 - 1991 Level B
Compact 3 Phase Voltage Monitor
TVM Series The NetTM
Motor Protector
Provides protection for motors and other sensitive loads. Continuously measures the voltage of each of the three phases using a new microcomputer circuit design that senses under and over voltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Includes a trip delay to prevent nuisance tripping and a restart delay to prevent short cycling after a momentary power outage.
-
Protects Against:
-
Fixed Trip Points and Delays
-
Fixed Voltages from 208 - 480 V AC
-
Isolated 10 A, SPDT Relay Contacts
-
Bi-color LED Indicator Shows: Output Status, Faults, Time Delays and Phase Reversal
- ASME A17.1 rule 210.6
-
NEMA MG1 14:30, 14:35
-
IEEE C62.41 - 1991 Level B
|