| Output Signal | Standard 2-wire: 4-20 mA / Vs = 12-36 Vdc Ex-protection: Vs = 14-28 Vdc Optional 3-wire: 0-20 mA / Vs = 14-36 Vdc 0-10 V / Vs = 14-36 Vdc |
| | |
| Accuracy | ±0.35% FSO BFSL Optional nominal pressure > 5 psi: <±0.25% FSO BFSL > 2 psi: <±0.1% FSO BFSL |
| | |
Permissible Load
| Current 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm Current 3-wire: Rmax = 500 Ohm Voltage 3-wire: Rmin = 10 kOhm
|
| | |
Influence Effects
| Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
| | |
Long-term Stability
| <±0.1% FSO/yr |
| | |
| Response Time | <10ms |
| | |
| Permissible Temperatures | Medium: 14°F to 158°F (-10°C to 70°C) Ex-protection Zone 0: 14°F to 140°F (-10°C to 60°C) Zone 1 or higher: 14°F to 158°F (-10°C to 70°C) Storage: -13°F to 158°F (-25°C to 70°C) |
| | |
| Reserve Polarity Protection | No damage. No function. |
| | |
| Electromagnetic Compatibility | Emission and immunity according to EN 61326 |
| | |
| Ex-protection Option | Zone 0: II 1 G Ex ia IIC T4 Zone 20: II 1 D Ex tD A20 IP65 T185°F (85°C) Safety technical max values: Vi = 28 V, Ii = 93 mA, Pi = 660 mW, Ci<1nF, L<10µH |
| | |
| Electrical Connection | Cable with sheath material: PVC grey, PUR black, FEP black, others available |
| | |
Pollution Degree
| 4, electrical equipment for outdoor use
|
| | |
Housing
| 316Ti SS
|
| | |
Seals
| FKM, others available
|
| | |
Diaphragm
| 316L SS
|
| | |
Weight
| 200 g (without cable) |
| | |
| Current Consumption | Current: 25 mA max Voltage: 7 mA max |
| | |
Connecting Cables
| Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m
|
| | |
Enclosure Rating
| NEMA 6P / IP68 |