DRIVE ISOLATION TRANSFORMERS by Hammond
HPS Drive Isolation Transformers are designed to meet the rugged demands of both AC and DC variable speed drives and also provide the required voltage change. The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load. The windings are designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds.
Drive Isolation Transformers are sized to match standard motor horsepower and voltage ratings. Standard sizes range from 5 to 600 HP in six standard voltages. Non-standard sizes and voltages are available upon request.
HPS offers two lines of Drive Isolation Transformers:
Energy Efficient Drive Isolation Transformers
HPS TribuneTM, Energy Efficient Drive Isolation Transformers, are designed to meet the rugged demands of both AC and DC variable speed drives and also provide the required voltage change. The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load. The windings are designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds.
Drive Isolation Transformers are sized to match standard motor horsepower and voltage ratings. Standard sizes range from 5 to 600 HP in six standard voltages. Non-standard sizes and voltages are available upon request.
Key features:
-
Meets US TP1 efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiencies at 35% of rated load (efficiencies are calculated under a linear load profile).
-
Ratings from 7.5 to 660 kVA
-
60 Hz frequency
-
Primary voltage: 208D, 230D, 460D, 480D, 575D
-
220°C (150°C rise) insulation system
-
Copper and aluminum available
-
UL listed
-
CSA certified
-
10 year warranty
-
Custom sizes, ratings and styles available upon request
For more information, click one of the links below:
Standard Drive Isolation Transformers
Standard Drive Isolation Transformers, are designed to meet the rugged demands of both AC and DC variable speed drives and also provide the requried voltage change. The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load. The windings are designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds.
Drive Isolation Transformers are sized to match standard motor horsepower and voltage ratings. Standard sizes range from 5 to 600 HP in six standard voltages. Non-standard sizes and voltages are available upon request.
Key features:
-
Ratings from 7.5 to 660 kVA
-
60 Hz frequency
-
Primary voltage: 208D, 230D, 460D, 480D, 575D
-
220°C (150°C rise) insulation system
-
Copper and Aluminum available
-
UL listed
-
CSA certified
-
10 year warranty
-
Custom sizes, ratings and styles available upon request
For more information, click one of the links below:
|